When choosing the appropriate photovoltaic modules, please first consider the following requirements:
The open-circuit voltage (Voc) of photovoltaic modules must not exceed the maximum open-circuit voltage that the inverter can withstand for solar panels
2. The open-circuit voltage (Voc) of the PV module should be higher than the starting voltage
| Solar charging model |
1.6 KW |
2.4 KW |
| System DC voltage |
12Vdc |
24Vdc |
| Maximum open-circuit voltage of photovoltaic array |
450Vdc |
450Vdc |
| Charging current |
80A |
80A |
| MPPT Optimal operating voltage |
90Vdc~430Vdc |
90Vdc~430Vdc |
This is a multifunctional inverter/charger that combines the functions of an inverter, a solar charger and a battery charger, providing uninterrupted power support in a portable size.
Its integrated LCD display offers user-configurable and easily accessible button operations, such as battery charging current, AC/solar charger priority, and acceptable input voltages based on different applications.



Features
- Pure sine wave inverter
The input voltage range of household appliances and personal computers can be configured through LCD Settings
The battery charging current based on the application can be configured through LCD Settings
The priority of the AC/solar charger can be configured through the LCD setting
- Compatible with the main power supply voltage or generator power supply
It automatically restarts when the AC power is restored
- Overload/over-temperature/short-circuit protection
- Smart battery charger design, optimizing battery performance
- Cold start function
- WIFI/GPRS(Option)
It can be connected to lithium batteries
| Model |
POW - HVM2.0 H - 12 v |
POW - HVM2.4 H - 24 v |
| Rated power |
1600VA/1600W |
3000VA/2400W |
| Input |
||
| Voltage |
230VAC |
|
| Optional voltage range |
170-280VAC (Personal computer) 90-280VAC (Household appliances) |
|
| Frequency range |
50Hz/60Hz (Automatic sensing) |
|
| Output |
||
| Ac voltage regulation (battery mode) |
230VAC±5% |
|
| Surge power |
3000W |
4800W |
| Efficiency (peak) PV to INV |
97% |
|
| Efficiency (peak) BAT to INV |
94% |
|
| Transmission time |
10ms (Personal computer) 20ms (Household appliances) |
|
| Waveform |
Pure sine wave |
|
| Battery & AC charger |
||
| Battery voltage |
12VDC |
24VDC |
| Float charging voltage |
13.5 VDC |
27VDC |
| Overcharge protection |
16VDC |
33VDC |
| Peak charging current |
60A |
|
| Solar charger |
||
| Peak photovoltaic array power |
2200W |
3000W |
| MPPT range @ operating voltage |
90-430VDC |
|
| Peak open-circuit voltage of photovoltaic array |
450VDC |
|
| Peak charging current |
80A |
|
| Peak efficiency |
98% |
|
| Conventional |
||
| "Size" |
348*270*95mm |
|
| Net weight (kg.s |
4Kg |
5Kg |
| Communication interface |
RS232(Standard) GPRS/WIFI(optional) |
|
| Operating environment |
||
| Humidity |
5% to 95% relative humidity (non-condensing) |
|
| Working temperature |
0℃to 55℃ |
|
| Storage temperature |
-15℃to 60℃ |
|
| INVERTER MODEL | 1.6KW 12V | 2.4KW 24V |
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); | |
| 100Vac±7V (Appliances) | ||
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz/ 60Hz (Auto-detection) | |
| Low Loss Frequency | 40±lHz | |
| Low Loss Return Frequency | 42±lHz | |
| High Loss Frequency | 65±lHz | |
| High Loss Return Frequency | 63±lHz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% ( Rated R load, battery full charged ) | |
| Transfer Time | 10ms typical (UPS); | |
| 20ms typical (Appliances) | ||
| INVERTER MODEL | 1.6KW 12V | 2.4KW 24V |
| Rated Output Power | 1.6 KW | 2.4 KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 91% | |
| Overload Protection | 5s@ >150% Io ad; 10s@ 110% ~ 150% Io ad | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 12Vdc | 24Vdc |
| Cold Start Voltage | 11.5 Vdc | 23.0 Vdc |
| Low DC Warning Voltage | 11.0 Vdc | 22.0 Vdc |
| @ Io ad < 50>% | 10.5 Vdc | 21.0 Vdc |
| @ load >50% | ||
| Low DC Warning Return Voltage | 11.5 Vdc | 22.5 Vdc |
| @ load < 50% | 11.0 Vdc | 22.0 Vdc |
| @ load >50% | ||
| Low DC Cut off Voltage | 10.2 Vdc | 20.5 Vdc |
| @ load < 50% | 9.6 Vdc | 20.0 Vdc |
| @ load >50% | ||
| High DC Recovery Voltage | 14.0 Vdc | 32Vdc |
| High DC Cut-off Voltage | 16.0 Vdc | 33Vdc |
| No Load Power Consumption | <25W | <30W |
| Utility Charging Mode | ||
| INVERTER MODEL | 1.6KW 12V | 2.4KW 24V |
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 60 Amp | |
| Bulk Charging Voltage | ||
| Flooded Battery | 14.6 | 29.2 |
| AGM / Gel Battery | 14.1 | 28.2 |
| Floating Charging Voltage | 13.5 Vdc | 27.0 Vdc |
| MPPT Solar Charging Mode | ||
| INVERTER MODEL | 1.6KW 12V | 2.4KW 24V |
| Max. PV Array Power | 2000W | 3000W |
| Nominal PV Voltage | 240Vdc | 240Vdc |
| PV Array MPPT Voltage Range | 90~430Vdc | 90~430Vdc |
| Max. PV Array Open Circuit Voltage | 450Vdc | 450Vdc |
| Max Charging Current (AC charger plus solar charger) | 80Amp | 80Amp |
| INVERTER MODEL | 1.6KW 12V | 2.4KW 24V |
| Safety Certification | CE | |
| Operating Temperature Range | -10°Cto50°C | |
| Storage temperature | -15°C~ 60° C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W* H), mm | 348X270X95 | |
| Net Weight, kg | 4 | 5 |












Note: The correct matching of system battery capacity should be determined based on the specific usage requirements of the load and application scenarios; otherwise, it may lead to insufficient battery capacity or excessive waste of power generation. For detailed information, please refer to the recommended manual or consult the online customer service. 